HiCell

Lightning Protection Device

1/2’’ Regular Cable

Main Features

  • High performance of attenuation

  • Wide frequency range

  • Low VSWR 

  • Widely used in RF solutions


Product Overview
Model List
Specification

Hicell 1/2’’ coaxial cable has high performance of attenuation, so it can be used in different RF systems, such as 3G/4G mobile communication. It can be used in various applications like indoor distribution, broadcast, base stations, wireless cellular and others. Low VSWR, perfect shielding effectiveness and extraordinary intermodulation performance lead to fewer energy loss and outer interference.


Model

HCCB-12R

Inner conductor(mm)

4.83

Dielectric(mm)

12.00

Outer conductor(mm)

13.84

Jacket (mm)

16.00

Min. single bending radius(mm)

125

Min. Repeated bending radius(mm)

250

Flat plate crush resistance (kg/mm2)

2.0

Max.pulling force(kg)

113

DC resistance
(?/km)

Inner conductor

1.62

Outer conductor

2.08

Insulation resistance (M?/km)

10000

Dielectric strength(kV)

6

Velocity of propagation(%)

88

Peak power rating (kW)

40

Max.operating frequency(GHz)

8

Characteristic impedance(?)

50±2

V.S.W.R  Max

?1.2

Operating temperature

Standard jacket

-40??+70?

Attenuation(@20?dB/100m)

Frequency (MHz)

Value

30

1.17

100

2.17

150

2.67

450

4.75

824

6.56

890

6.84

960

7.12

1000

7.28

1700

9.74

1800

10.10

2000

10.70

2300

11.60

3000

13.51

Average Power (@Ambient 40?, Inner conductor 100?)

Frequency (MHz)

Value

30

6.26

100

3.43

150

2.79

450

1.56

824

1.13

890

1.08

960

1.05

1000

1.02

1700

0.76

1800

0.74

2000

0.70

2300

0.64

3000

0.55


Model

HCCB-12R

Inner conductor(mm)

4.83

Dielectric(mm)

12.00

Outer conductor(mm)

13.84

Jacket (mm)

16.00

Min. single bending radius(mm)

125

Min. Repeated bending radius(mm)

250

Flat plate crush resistance (kg/mm2)

2.0

Max.pulling force(kg)

113

DC resistance
(?/km)

Inner conductor

1.62


Outer conductor

2.08

Insulation resistance (M?/km)

10000

Dielectric strength(kV)

6

Velocity of propagation(%)

88

Peak power rating (kW)

40

Max.operating frequency(GHz)

8

Characteristic impedance(?)

50±2

V.S.W.R  Max

?1.2

Operating temperature

Standard jacket

-40??+70?

Attenuation(@20?dB/100m)

Frequency (MHz)

Value

30

1.17

100

2.17

150

2.67

450

4.75

824

6.56

890

6.84

960

7.12

1000

7.28

1700

9.74

1800

10.10

2000

10.70

2300

11.60

3000

13.51

Average Power (@Ambient 40?, Inner conductor 100?)

Frequency (MHz)

Value

30

6.26

100

3.43

150

2.79

450

1.56

824

1.13

890

1.08

960

1.05

1000

1.02

1700

0.76

1800

0.74

2000

0.70

2300

0.64

3000

0.55